Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Dental press j. orthod. (Impr.) ; 17(4): 51-56, July-Aug. 2012. ilus
Article in English | LILACS | ID: lil-653501

ABSTRACT

OBJECTIVE: The aim of this study was to assess resistance to sliding of stainless steel passive self-ligating brackets with 0° and 2.5° angulations and to compare them to active self-ligating brackets at zero angulation. The hypothesis to be tested was that passive self-ligating brackets produce lower frictional forces than active self-ligating brackets. METHODS: Twenty five 0.022 x 0.028-in slot maxillary canine brackets were divided into 5 groups of 5 brackets: Damon SL II (Ormco, CA, USA) self-ligating bracket and Gemini (3M/Unitek, CA, USA) conventional bracket with angulation of 0 and 2.5° and a group of Speed 2 (American Orthodontics, WI, USA) active clip self-ligating system with zero angulation. Twenty five segments of stainless steel 0.020-in archwire (TP Orthodontics, IN, USA) were tested and each bracket/wire interface was evaluated at 4 successive points during sliding. Overall, 100 frictional values were analyzed by parametric analysis of variance and Bonferroni tests. RESULTS AND CONCLUSION: Frictional tests were performed with an Emic DL 10000 testing machine (Emic, Brazil) with a load cell of one kilogram. Passive self-ligating brackets produced lower frictional forces than active self-ligating brackets (p < 0.01). Under angulation, brackets with a slide mechanism produced higher friction than the same brackets under zero angulation (p < 0.01). Nevertheless, the slide system under angulation produced smaller friction values than conventional brackets tied with elastomeric ligatures in 0° tests.


OBJETIVO: avaliar a fricção apresentada por braquetes autoligáveis de aço inoxidável com sistema passivo de tampa deslizante sob angulação de 0 grau e 2,5 graus, e comparar o comportamento desse grupo sob angulação nula com o de um grupo de braquetes autoligáveis com sistema ativo de tampa resiliente. MÉTODOS: foram utilizados 25 braquetes de caninos superiores, divididos em 5 grupos - braquetes autoligáveis passivos Damon SL II sob angulação de 0 grau e de 2,5 graus; braquetes convencionais Gemini amarrados com ligaduras elásticas sob as mesmas angulações; e um grupo formado pelo sistema ativo Time 2, sob angulação nula. A hipótese a ser testada é se artefatos autoligáveis com sistema de tampa passiva são mais efetivos no controle da fricção do que dispositivos contendo coberturas ativas. O tracionamento foi realizado segundo emprego de 25 segmentos de fio de aço inoxidável 0,020" na máquina de ensaios EMIC DL 10000 com célula de carga de 2,0kg. Cada conjunto braquete/fio foi responsável pela geração de quatro corpos de prova, totalizando-se 100 leituras. As comparações entre médias dos valores foram realizadas através da Análise de Variância (one-way ANOVA) com correções pelo coeficiente de Bonferroni. RESULTADOS E CONCLUSÃO: as médias de fricção encontradas confirmaram a hipótese em teste, de que o sistema de braquetes Damon SL II é mais eficiente no controle do atrito do que o sistema de tampa ativa sob angulação de 0 grau (p<0,01). Quando submetidos a angulações de 2,5 graus, a fricção aumentou significativamente (p<0,01), porém mantendo-se ainda muito inferior aos patamares evidenciados no grupo de braquetes convencionais amarrados com ligaduras elásticas.

2.
Dental press j. orthod. (Impr.) ; 16(4): 35.e1-35.e7, jul.-ago. 2011. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-604321

ABSTRACT

OBJETIVO: o objetivo do presente trabalho foi determinar a força de atrito estático entre braquetes de aço inoxidável autoligados com sistema de fechamento resiliente e fios ortodônticos redondos e retangulares do mesmo material. MÉTODOS: empregaram-se 30 braquetes referentes aos caninos superiores divididos em 6 grupos formados por braquetes autoligados Smartclip, In-Ovation R e convencionais Gemini amarrados com ligaduras elásticas. A hipótese testada neste trabalho foi quanto à possibilidade dos braquetes autoligados ativos serem suscetíveis à elevação da força de atrito com o aumento e alteração da secção transversal dos fios ortodônticos. Os ensaios foram realizados com tração de 30s em fios de aço inoxidável 0,020" e 0,019"X0,025" na máquina de ensaios Emic DL 10000, com uma célula de carga de 20 newtons. Cada conjunto braquete/fio foi responsável pela geração de quatro corpos de prova, totalizando 120 leituras. As comparações entre as médias foram realizadas através da Análise de Variância (one way ANOVA) com correções pelo coeficiente de Bonferroni. RESULTADOS E CONCLUSÃO: os braquetes autoligados apresentaram maior força de atrito do que os braquetes convencionais amarrados com ligaduras elásticas. O grupo Smartclip foi o mais efetivo no controle do atrito (p<0,01). A hipótese em teste, influência da forma da seção transversal do fio na força de atrito, foi confirmada, uma vez que os fios de secção retangular 0,019"X0,025" apresentaram maior força de atrito ao serem tracionados do que os fios redondos 0,020" (p<0,01). O sistema Smartclip foi mais efetivo mesmo quando o tracionamento de fios retangulares foi comparado com o ensaio de braquetes In-Ovation R conjugados a fios redondos (p<0,01).


OBJECTIVES: The purpose of this study was to assess the surface friction produced by self-ligating stainless steel brackets equipped with a resilient closure system and compare the friction generated during traction of round and rectangular orthodontic wires made from the same material. METHODS: Thirty maxillary canine brackets were divided into six groups comprising SmartClip and In-Ovation R self-ligating brackets, and conventional Gemini brackets tied with elastomeric ligatures. This investigation tested the hypothesis that self-ligating brackets are susceptible to increases in friction that are commensurate with increases and changes in the cross-section of orthodontic wires. Traction was performed with the aid of thirty segments of 0.020" and 0.019" x 0.025" stainless steel wires in an EMIC DL 10000 testing machine with a 2N load cell. Each set of bracket/wire generated four samples, totaling 120 readings. Comparisons between means were performed using analysis of variance (one way ANOVA) corrected with the Bonferroni coefficient. RESULTS AND CONCLUSION: The self-ligating brackets exhibited lower friction than conventional brackets tied with elastomeric ligatures. The SmartClip group was the most effective in controlling friction (p <0.01). The hypothesis under test was confirmed to the extent that the traction performed with rectangular 0.019" x 0.025" cross-section wires resulted in higher friction forces than those observed in the 0.020" round wire groups (p<0.01). The SmartClip system was more effective even when the traction produced by rectangular wires was compared with the In-Ovation R brackets combined with round wires (p<0.01).


Subject(s)
Orthodontic Brackets , Friction , Orthodontic Wires , Stainless Steel , Orthodontics
3.
Rev. dent. press ortodon. ortopedi. facial ; 13(3): 97-103, maio-jun. 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-484629

ABSTRACT

INTRODUÇÃO: os braquetes autoligáveis foram, inicialmente, idealizados com objetivo de otimização do tempo de atendimento clínico. Por dispensar qualquer tipo de amarração, inúmeras vantagens foram atribuidas a este sistema, com a redução da fricção superficial na interface braquete/fio ortodôntico. Com esta redução, são necessárias forças de menor intensidade para o estabelecimento da movimentação dentária, realizada, assim, de uma forma mais rápida e eficiente. Em decorrência da maior demanda estética por parte dos pacientes, os braquetes autoligáveis começaram a ser confeccionados em policarbonato, promovendo ganhos estéticos únicos, quando em comparação a seus anólogos metálicos. OBJETIVO: realizar uma revisão de literatura sobre o sistema de braquetes autoligáveis estéticos.


INTRODUCTION: The self-ligating system was introduced aiming the reduction of chair time. Once this system does not need any ligation form, several advantages were observed, such as the reduction on superficial friction in couple bracket/ orthodontic wire, and the reduction on the force level that is necessary to establish the orthodontic tooth movement. The growing demands of aesthetic patients induced the self-ligating system to be made of polycarbonate material, resulting in unique aesthetic advantages when compared with the metallic form of this system. AIM: The objective of this paper was to proceed with a literature review about aesthetic self-ligating brackets.


Subject(s)
Orthodontic Brackets/trends , Esthetics, Dental , Dental Materials , Friction
4.
Rev. bras. odontol ; 60(3): 208-212, maio-jun. 2003. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-404198

ABSTRACT

No presente estudo, o índice PAR (Peer Assessment Rating) foi aplicado em modelos de pacientes tratados na Clínica de Ortodontia da UERJ com o objetivo de investigar a relação entre a duração da intervenção ortodôntica com a severidade inicial da maloclusão e o grau de melhora do caso. Pesquisou-se também quais as caracteríticas oclusais que mais contribuíram para a caracterização da maloclusão e aquelas que obtiveram maior melhora decorrente do tratamento ortodôntico. O componente ântero-superior do índice foi o que mais contribuiu para a classificação inicial, bem como para a a melhora do caso ao final da intervenção


Subject(s)
Humans , Male , Female , Dental Occlusion , Malocclusion/therapy , Outcome and Process Assessment, Health Care
5.
Ortodon. gaúch ; 6(2): 116-28, jul.-dez. 2002. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-852988

ABSTRACT

Os índices oclusais têm sido bastante utilizados, nos últimos anos, no estudo da epidemiologia da maloclusão, bem como na análise da qualidade dos tratamentos ortodônticos realizados, principalmente nos países do norte da Europa. O emprego de um índice válido e reproduzível é essencial para que dados provenientes de diferentes grupos, ou até do mesmo grupo em diferentes momentos, possam ser comparados. Recentemente, na Inglaterra, foram desenvolvidos dois índices, o IOTN e o PAR, que parecem preencher os pré-requisitos para serem considerados como aceitáveis. A utilização desses métodos de avaliação da necessidade e do sucesso do tratamento pode nos fornecer dados que nos permitem estabelecer uma clara visão da relação risco/benefício do tratamento ortodôntico e, conseqüentemente, do real valor da intervenção para a população


Subject(s)
Humans , Male , Female , Dental Occlusion , Malocclusion/epidemiology
6.
J. bras. ortodon. ortop. facial ; 4(24): 516-525, nov.-dez. 1999. tab, graf, CD-ROM
Article in Portuguese | LILACS, BBO | ID: biblio-851226

ABSTRACT

A Ortodontia é uma especialidade com risco de contaminação cruzada, porém seu controle de infecção ainda é insuficiente por grande parte dos profissionais. O objetivo do presente trabalho foi avaliar a efetividade de métodos de controle de infecção em alicates ortôndicos para Estreptococus orais. Utilizaram-se 3 grupos de alicates que, após uso clínico, foram submetidos a diferentes condutas: Grupo A (n=31) exposição ao ar por 2 horas; Grupo D (n=29) desinfecção em álcool 70 por cento iodado; Grupo E (n=30) esterilização em autoclave. A avalição microbiológica consistiu em semeadura da parte ativa do alicate em meio seletivo para Estreptococos orais (caldo mitis salivarius) e, após a incubação, verificou-se a presença ou não desses microorganismos. Através dos resultados, pôde-se concluir que os grupos A, D e E apresentaram respectivamente 93,55 por cento, 24,14 por cento e 0 por cento de contaminação. Houve diferença estatisticamente significativa entre os 3 grupos (H=43.221 P<.05). Comparando-se A x D e A x E também houve diferença com significância em nível estatístico, o que não ocorreu entre D x E (teste de comparação Dunn's). Podemos concluir que a efetividade dos métodos de controle de infecção utilizados somente esteve em um patamar aceitável quando a esterilização (calor úmido sob pressão) foi realizada


Subject(s)
Methods , Microbiology , Microbiology
7.
J. bras. ortodon. ortop. facial ; 4(23): 414-423, set.-out. 1999. ilus, CD-ROM
Article in Portuguese | LILACS, BBO | ID: biblio-851216

ABSTRACT

O presente artigo descreve a mecânica de intrusão relativa de incisivos e relata o tratamento ortodôntico de uma paciente adulta, a qual apresentava sobremordida exagerada, cujo tratamento forneceu uma melhora considerável nos aspectos funcional e estético. Considerações são feitas sobre as particularidades do tratamento ortodôntico de pacientes adultos e para a necessidade de uma contenção bem planejada e aplicada, após a correção da sobremordida exagerada


Subject(s)
Humans , Female , Adult , Therapeutics
SELECTION OF CITATIONS
SEARCH DETAIL